Small L- Plate (Left & Right)
 Small L- Plate (Left & Right)

Small L- Plate (Left & Right)

DESCRIPTION

Dorsal Distal Radius Plates are indicated for the fixation of Intra and Extra Articular Fractures and Osteotomies of the Distal Radius from dorsal site. Make a longitudnal incision for fixing the plate slightly radial to the flexor carpi radialis tendon, dissect the flexor carpi radialis taking care of radial artery and by exposing and detaching apronator quadratus from lateral border of the radius and elevate it toward the ulna, proximally incision depends on the pattern and length of plate used.

Screw option: 2.7mm Cortical Screw

SUITABLE FOR DISTAL RADIUS FRACTURE
SCREW 3.5MM
PROFILE 25.0MM / 11.0MM X 2.0MM
DISTANCE BETWEEN HOLE 9.0MM
MATERIAL STAINLESS STEEL 316L / 316LVM / TITANIUM
HOLES 3,4,5,6,7,8,9,10,11,12
PROXIMAL / DISTAL SCREW CORTICAL SCREW 3.5MM
SCREW LENGTH 10.0MM TO 36.0MM (DIFF. 2.0MM)
DESCRIPTION


LEFT RIGHT
HOLE CAT. No. S.S. CAT. No. TIT. CAT. No. S.S. CAT. No. TIT.
 
03 HOLE S23.SS01436 S23.TIT01436 S23.SS01446 S23.TIT01446
04 HOLE S23.SS01437 S23.TIT01437 S23.SS01447 S23.TIT01447
05 HOLE S23.SS01438 S23.TIT01438 S23.SS01448 S23.TIT01448
06 HOLE S23.SS01439 S23.TIT01439 S23.SS01449 S23.TIT01449
07 HOLE S23.SS01440 S23.TIT01440 S23.SS01450 S23.TIT01450
08 HOLE S23.SS01441 S23.TIT01441 S23.SS01451 S23.TIT01451
09 HOLE S23.SS01442 S23.TIT01442 S23.SS01452 S23.TIT01452
10 HOLE S23.SS01443 S23.TIT01443 S23.SS01453 S23.TIT01453
11 HOLE S23.SS01444 S23.TIT01444 S23.SS01454 S23.TIT01454
12 HOLE S23.SS01445 S23.TIT01445 S23.SS01455 S23.TIT01455

Latest Videos

Upcoming Events

About US

We are one of the first three companies of India to obtain Indian FDA (CDSCO) permission to manufacture Orthopedic Implants. We offer a wide & growing range of the highest quality orthopedic implants & instrumentation along with other associated product sat reasonable cost. We have got a sound and firm position in the orthopedic industry by having a sturdy network of distributors domestically & around the globe. We are having the most modern technologies and are one of the leading manufacturers (since 1992) with pinnacle superiority of Ortho-Implants and instrumentation's.
Read More...

Membership
  • US FDA
  • Indian FDA
  • Federation of Gujarat Industries (FGI)
  • Federation of Indian Chambers of Commerce and Industry(FICCI)
  • Orthopedic implants Manufacturer asosiationasosiation
DKSORTHO & Sharma Pharmaceutical Pvt. Ltd..

Address:
444, G.I.D.C Estate , Waghodia -391 760, Vadodara, Gujarat, India

Contact: +91-9825027792, 9227703191

Email: info@spcpl.com;

Website: https://www.spcpl.com

Copyright © 2018 DKSORTHO & Sharma Pharmaceutical Pvt. Ltd., All Rights Reserved.
Design and Develop by Shri Narayan Infotech
Orthopedic Implants, Orthopaedic, Manufacturer,Small Fragment – NonLocked, Small Fragment Implants- Small L- Plate (Left & Right),Small Fragment – NonLocked,Small Fragment Implants, Small L- Plate (Left & Right)