Pelvic Curved Locked Plate
Pelvic Curved Locked Plate

Pelvic Curved Locked Plate

DESCRIPTION

INDICATIONS: Quadrilateral surface combination associated with acetabular fracture, Sacrum Fracture, Posterior Iliac Fracture APPROACH: • The standard horizontal approach to the symphysis is used for reduction and fixation of the Pubis and medial Ramus fractures. • For more lateral exposure of the pubic Ramus, a lateral extension of the standard approach or a modified Stoppa incision may be necessary. • For access to an unstable iliac wing fracture, or the anterior part of the SI joint, including suitable crescent fractures, the anterior approach to the iliac wing is necessary.

Screw option: 4.0mm Cortex Locked Screw

Suitable for Pelvic Ring, Internal & external aspect of the ilium. Posterior wall & anterior wall or wall fracture
Screw 4.0mm
Profile 10.0mm x 3.0mm
Distance between hole 13.0mm
Material Stainsless Steel 316L, 316LVM Tatanium
DESCRIPTION
Holes 2 Hole to 20 Hole (Diff. 1 Hole)
Screw Cortex Locked Screw 4.0mm
Screw Length 10.0mm to 40.0mm (Diff. 2.0mm)
Screw Cancellous Locked Screw 4.0mm
Screw Length 10.0mm to 80.0mm


HOLE CAT. No. S.S. CAT. No. TIT.
 
02 S23.SS26456 S23.TIT26456
03 S23.SS26457 S23.TIT26457
04 S23.SS04196 S23.TIT04196
05 S23.SS04197 S23.TIT04197
06 S23.SS04198 S23.TIT04198
07 S23.SS04199 S23.TIT04199
08 S23.SS04200 S23.TIT04200
09 S23.SS04201 S23.TIT04201
10 S23.SS04202 S23.TIT04202
11 S23.SS04203 S23.TIT04203
12 S23.SS04204 S23.TIT04204
13 S23.SS04205 S23.TIT04205
14 S23.SS04206 S23.TIT04206
15 S23.SS04207 S23.TIT04207
16 S23.SS04208 S23.TIT04208
17 S23.SS04209 S23.TIT04209
18 S23.SS04210 S23.TIT04210
19 S23.SS04211 S23.TIT04211
20 S23.SS04212 S23.TIT04212

Latest Videos

Upcoming Events

About US

We are one of the first three companies of India to obtain Indian FDA (CDSCO) permission to manufacture Orthopedic Implants. We offer a wide & growing range of the highest quality orthopedic implants & instrumentation along with other associated product sat reasonable cost. We have got a sound and firm position in the orthopedic industry by having a sturdy network of distributors domestically & around the globe. We are having the most modern technologies and are one of the leading manufacturers (since 1992) with pinnacle superiority of Ortho-Implants and instrumentation's.
Read More...

Membership
  • US FDA
  • Indian FDA
  • Federation of Gujarat Industries (FGI)
  • Federation of Indian Chambers of Commerce and Industry(FICCI)
  • Orthopedic implants Manufacturer asosiationasosiation
DKSORTHO & Sharma Pharmaceutical Pvt. Ltd..

Address:
444, G.I.D.C Estate , Waghodia -391 760, Vadodara, Gujarat, India

Contact: +91-9825027792, 9227703191

Email: info@spcpl.com;

Website: https://www.spcpl.com

Copyright © 2018 DKSORTHO & Sharma Pharmaceutical Pvt. Ltd., All Rights Reserved.
Design and Develop by Shri Narayan Infotech
Orthopedic Implants, Orthopaedic, Manufacturer,Large Fragment - Locked-Locked Plate Implants-Pelvic Curved Locked Plate,Large Fragment - Locked,Locked Plate Implants,Pelvic Curved Locked Plate