Low Profile Proximal Lateral Tibia Locked Plate (Left & Right)
 Low Profile Proximal Lateral Tibia Locked Plate (Left & Right)

Low Profile Proximal Lateral Tibia Locked Plate (Left & Right)

DESCRIPTION

These types of plates are mainly made for Lateral Condylar Fracture associated with Shaft Fractures. Plates can also be used for treatment of Non unions, Tibial Osteotomies and Osteopenic Bone. In the presence of a complex Intra-Articular Fracture, an anterolateral approach can be performed.


Screw option: 4.0mm Cancellous/4.0mm Cortex Locked Screw,

SUITABLE FOR PROXIMAL LATERAL TIBIA FRACTURES
SCREW 4.0MM
PROFILE 33.0MM / 12.0MM X 4.0MM
DISTANCE BETWEEN HOLE 13.0MM
MATERIAL STAINLESS STEEL 316L / 316LVM / TITANIUM
HOLES 2,3,4,5,6,7,8,9,10,11,12,13,14,15
PROXIMAL SCREW CANCELLOUS LOCKED SCREW 40MM
SCREW LENGTH 10.0MM TO 60.0MM (DIFF. 2.0MM)
DISTAL SCREW CORTEX LOCKED SCREW 4.0MM
SCREW LENGTH 10.0MM TO 40.0MM (DIFF. 2.0MM)
DESCRIPTION


LEFT RIGHT
HOLE CAT. No. S.S. CAT. No. TIT. CAT. No. S.S. CAT. No. TIT.
 
02 SP05.SS00581 SP05.TIT00581 SP05.SS00595 SP05.TIT00595
03 SP05.SS00582 SP05.TIT00582 SP05.SS00596 SP05.TIT00596
04 SP05.SS00583 SP05.TIT00583 SP05.SS00597 SP05.TIT00597
05 SP05.SS00584 SP05.TIT00584 SP05.SS00598 SP05.TIT00598
06 SP05.SS00585 SP05.TIT00585 SP05.SS00599 SP05.TIT00599
07 SP05.SS00586 SP05.TIT00586 SP05.SS00600 SP05.TIT00600
08 SP05.SS00587 SP05.TIT00587 SP05.SS00601 SP05.TIT00601
09 SP05.SS00588 SP05.TIT00588 SP05.SS00602 SP05.TIT00602
10 SP05.SS00589 SP05.TIT00589 SP05.SS00603 SP05.TIT00603
11 SP05.SS00590 SP05.TIT00590 SP05.SS00604 SP05.TIT00604
12 SP05.SS00591 SP05.TIT00591 SP05.SS00605 SP05.TIT00605
13 SP05.SS00592 SP05.TIT00592 SP05.SS00606 SP05.TIT00606
14 SP05.SS00593 SP05.TIT00593 SP05.SS00607 SP05.TIT00607
15 SP05.SS00594 SP05.TIT00594 SP05.SS00608 SP05.TIT00608

Latest Videos

Upcoming Events

About US

We are one of the first three companies of India to obtain Indian FDA (CDSCO) permission to manufacture Orthopedic Implants. We offer a wide & growing range of the highest quality orthopedic implants & instrumentation along with other associated product sat reasonable cost. We have got a sound and firm position in the orthopedic industry by having a sturdy network of distributors domestically & around the globe. We are having the most modern technologies and are one of the leading manufacturers (since 1992) with pinnacle superiority of Ortho-Implants and instrumentation's.
Read More...

SHARMA PHARMACEUTICAL PVT. LTD.

Address:
444, G.I.D.C Estate , Waghodia -391 760, Vadodara, Gujarat, India

Contact: +91-9825027792, 9227703191

Email: info@spcpl.com;

Website: https://www.spcpl.com

Copyright © 2018 Sharma Pharmaceutical Pvt. LTd, All Rights Reserved.
Design and Develop by Shri Narayan Infotech
Orthopedic Implants, Orthopaedic, Manufacturer,Large Fragment - Locked-Locked Plate Implants- Low Profile Proximal Lateral Tibia Locked Plate (Left & Right),Large Fragment - Locked,Locked Plate Implants, Low Profile Proximal Lateral Tibia Locked Plate (Left & Right)