L - Butteress Locked Plate (Left & Right)
 L - Butteress Locked Plate (Left & Right)

L - Butteress Locked Plate (Left & Right)

DESCRIPTION

Plates are used in Proximal Lateral Tibial Fracture, Lateral Condylar Fracture, Metaphyseal combination in the Tibia Lateral approach and Antero Lateral incision is made for fixing the plate.

Screw option:5.0mm cancellous locked screw, 5.0mm Cortex


SUITABLE FOR PROXIMAL TIBIA FRACTURE
SCREW 5.0MM
PROFILE 37.0MM / 16.0MM X 3.0MM
DISTANCE BETWEEN HOLE 16.0MM
MATERIAL STAINLESS STEEL 316L / 316LVM / TITANIUM
HOLES 2,3,4,5,6,7,8,9,10,11,12
PROXIMAL SCREW CANCELLOUS LOCKED SCREW 5.0MM
SCREW LENGTH 20.0MM TO 64.0MM (DIFF. 2.0MM)
PROXIMAL / DISTAL SCREW CORTEX LOCKED SCREW 5.0MM
SCREW LENGTH 20.0MM TO 64.0MM (DIFF. 20MM)
DESCRIPTION


LEFT RIGHT
HOLE CAT. No. S.S. CAT. No. TIT. CAT. No. S.S. CAT. No. TIT.
 
02 SP05.SS00188 SP05.TIT00188 SP05.SS00199 SP05.TIT00199
03 SP05.SS00189 SP05.TIT00189 SP05.SS00200 SP05.TIT00200
04 SP05.SS00190 SP05.TIT00190 SP05.SS00201 SP05.TIT00201
05 SP05.SS00191 SP05.TIT00191 SP05.SS00202 SP05.TIT00202
06 SP05.SS00192 SP05.TIT00192 SP05.SS00203 SP05.TIT00203
07 SP05.SS00193 SP05.TIT00193 SP05.SS00204 SP05.TIT00204
08 SP05.SS00194 SP05.TIT00194 SP05.SS00205 SP05.TIT00205
09 SP05.SS00195 SP05.TIT00195 SP05.SS00206 SP05.TIT00206
10 SP05.SS00196 SP05.TIT00196 SP05.SS00207 SP05.TIT00207
11 SP05.SS00197 SP05.TIT00197 SP05.SS00208 SP05.TIT00208
12 SP05.SS00198 SP05.TIT00198 SP05.SS00209 SP05.TIT00209

Latest Videos

Upcoming Events

About US

We are one of the first three companies of India to obtain Indian FDA (CDSCO) permission to manufacture Orthopedic Implants. We offer a wide & growing range of the highest quality orthopedic implants & instrumentation along with other associated product sat reasonable cost. We have got a sound and firm position in the orthopedic industry by having a sturdy network of distributors domestically & around the globe. We are having the most modern technologies and are one of the leading manufacturers (since 1992) with pinnacle superiority of Ortho-Implants and instrumentation's.
Read More...

SHARMA PHARMACEUTICAL PVT. LTD.

Address:
444, G.I.D.C Estate , Waghodia -391 760, Vadodara, Gujarat, India

Contact: +91-9825027792, 9227703191

Email: info@spcpl.com;

Website: https://www.spcpl.com

Copyright © 2018 Sharma Pharmaceutical Pvt. LTd, All Rights Reserved.
Design and Develop by Shri Narayan Infotech
Orthopedic Implants, Orthopaedic, Manufacturer,Large Fragment - Locked-Locked Plate Implants- L - Buttress Locked Plate (Left & Right),Large Fragment - Locked,Locked Plate Implants, L - Buttress Locked Plate (Left & Right)