L - Butteress Locked Plate (Left & Right)
 L - Butteress Locked Plate (Left & Right)

L - Butteress Locked Plate (Left & Right)

DESCRIPTION

Plates are used in Proximal Lateral Tibial Fracture, Lateral Condylar Fracture, Metaphyseal combination in the Tibia Lateral approach and Antero Lateral incision is made for fixing the plate.

Screw option:5.0mm cancellous locked screw, 5.0mm Cortex


SUITABLE FOR PROXIMAL TIBIA FRACTURE
SCREW 5.0MM
PROFILE 37.0MM / 16.0MM X 3.0MM
DISTANCE BETWEEN HOLE 16.0MM
MATERIAL STAINLESS STEEL 316L / 316LVM / TITANIUM
HOLES 2,3,4,5,6,7,8,9,10,11,12
PROXIMAL SCREW CANCELLOUS LOCKED SCREW 5.0MM
SCREW LENGTH 20.0MM TO 64.0MM (DIFF. 2.0MM)
PROXIMAL / DISTAL SCREW CORTEX LOCKED SCREW 5.0MM
SCREW LENGTH 20.0MM TO 64.0MM (DIFF. 20MM)
DESCRIPTION


LEFT RIGHT
HOLE CAT. No. S.S. CAT. No. TIT. CAT. No. S.S. CAT. No. TIT.
 
02 S23.SS00188 S23.TIT00188 S23.SS00199 S23.TIT00199
03 S23.SS00189 S23.TIT00189 S23.SS00200 S23.TIT00200
04 S23.SS00190 S23.TIT00190 S23.SS00201 S23.TIT00201
05 S23.SS00191 S23.TIT00191 S23.SS00202 S23.TIT00202
06 S23.SS00192 S23.TIT00192 S23.SS00203 S23.TIT00203
07 S23.SS00193 S23.TIT00193 S23.SS00204 S23.TIT00204
08 S23.SS00194 S23.TIT00194 S23.SS00205 S23.TIT00205
09 S23.SS00195 S23.TIT00195 S23.SS00206 S23.TIT00206
10 S23.SS00196 S23.TIT00196 S23.SS00207 S23.TIT00207
11 S23.SS00197 S23.TIT00197 S23.SS00208 S23.TIT00208
12 S23.SS00198 S23.TIT00198 S23.SS00209 S23.TIT00209

Latest Videos

Upcoming Events

About US

We are one of the first three companies of India to obtain Indian FDA (CDSCO) permission to manufacture Orthopedic Implants. We offer a wide & growing range of the highest quality orthopedic implants & instrumentation along with other associated product sat reasonable cost. We have got a sound and firm position in the orthopedic industry by having a sturdy network of distributors domestically & around the globe. We are having the most modern technologies and are one of the leading manufacturers (since 1992) with pinnacle superiority of Ortho-Implants and instrumentation's.
Read More...

Membership
  • US FDA
  • Indian FDA
  • Federation of Gujarat Industries (FGI)
  • Federation of Indian Chambers of Commerce and Industry(FICCI)
  • Orthopedic implants Manufacturer asosiationasosiation
DKSORTHO & Sharma Pharmaceutical Pvt. Ltd..

Address:
444, G.I.D.C Estate , Waghodia -391 760, Vadodara, Gujarat, India

Contact: +91-9825027792, 9227703191

Email: info@spcpl.com;

Website: https://www.spcpl.com

Copyright © 2018 DKSORTHO & Sharma Pharmaceutical Pvt. Ltd., All Rights Reserved.
Design and Develop by Shri Narayan Infotech
Orthopedic Implants, Orthopaedic, Manufacturer,Large Fragment - Locked-Locked Plate Implants- L - Buttress Locked Plate (Left & Right),Large Fragment - Locked,Locked Plate Implants, L - Buttress Locked Plate (Left & Right)