Lateral Tibia Head Buttress Locked Plate ( Left & Right)
 Lateral Tibia Head Buttress Locked Plate ( Left & Right)

Lateral Tibia Head Buttress Locked Plate ( Left & Right)

DESCRIPTION

Indications are Articular fracture, Intraarticular fracture, Fracture of tibial plateau, Metaphyseal fracture Approach for fixation is Straight skin incision from gerdy’s tubercle about 50mm in distal direction.

Screw option: 6.5mm Cancellous/5.0mm Cortex Locked Screw,

SUITABLE FOR PROXIMAL LATERAL TIBIA FRACTURES
SCREW 6.5MM & 5.0MM
PROFILE 36.0MM / 14.0 X 5.0MM
DISTANCE BETWEEN HOLE 18.0MM
MATERIAL STAINLESS STEEL 316L / 316LVM / TITANIUM
HOLES 2 Hole to 20 Hole
PROXIMAL SCREW CANCELLOUS LOCKED SCREW 6.5MM
SCREW LENGTH 20.0MM TO 100.0MM (DIFF. 5.0MM)
DISTAL SCREW CORTEX LOCKED SCREW 5.0MM
SCREW LENGTH 20.0MM TO 64.0MM (DIFF. 2.0MM)
DESCRIPTION


left Right
HOLE CAT. No. S.S. CAT. No. TIT. CAT. No. S.S. CAT. No. TIT.
 
02 S23.SS00043 S23.TIT00043 S23.SS00060 S23.TIT00060
03 S23.SS00044 S23.TIT00044 S23.SS00061 S23.TIT00061
04 S23.SS00045 S23.TIT00045 S23.SS00062 S23.TIT00062
05 S23.SS00046 S23.TIT00046 S23.SS00063 S23.TIT00063
06 S23.SS00047 S23.TIT00047 S23.SS00064 S23.TIT00064
07 S23.SS00048 S23.TIT00048 S23.SS00065 S23.TIT00065
08 S23.SS00049 S23.TIT00049 S23.SS00066 S23.TIT00066
09 S23.SS00050 S23.TIT00050 S23.SS00067 S23.TIT00067
10 S23.SS00051 S23.TIT00051 S23.SS00068 S23.TIT00068
11 S23.SS00052 S23.TIT00052 S23.SS00069 S23.TIT00069
12 S23.SS00053 S23.TIT00053 S23.SS00070 S23.TIT00070
13 S23.SS00054 S23.TIT00054 S23.SS00071 S23.TIT00071
14 S23.SS00055 S23.TIT00055 S23.SS00072 S23.TIT00072
15 S23.SS00056 S23.TIT00056 S23.SS00073 S23.TIT00073
16 S23.SS00057 S23.TIT00057 S23.SS00074 S23.TIT00074
17 S23.SS00058 S23.TIT00058 S23.SS00075 S23.TIT00075
18 S23.SS00059 S23.TIT00059 S23.SS00076 S23.TIT00076
19 S23.SS28686 S23.TIT28686 S23.SS28691 S23.TIT28691
20 S23.SS28687 S23.TIT28687 S23.SS28692 S23.TIT28692

Latest Videos

Upcoming Events

About US

We are one of the first three companies of India to obtain Indian FDA (CDSCO) permission to manufacture Orthopedic Implants. We offer a wide & growing range of the highest quality orthopedic implants & instrumentation along with other associated product sat reasonable cost. We have got a sound and firm position in the orthopedic industry by having a sturdy network of distributors domestically & around the globe. We are having the most modern technologies and are one of the leading manufacturers (since 1992) with pinnacle superiority of Ortho-Implants and instrumentation's.
Read More...

Membership
  • US FDA
  • Indian FDA
  • Federation of Gujarat Industries (FGI)
  • Federation of Indian Chambers of Commerce and Industry(FICCI)
  • Orthopedic implants Manufacturer asosiationasosiation
DKSORTHO & Sharma Pharmaceutical Pvt. Ltd..

Address:
444, G.I.D.C Estate , Waghodia -391 760, Vadodara, Gujarat, India

Contact: +91-9825027792, 9227703191

Email: info@spcpl.com;

Website: https://www.spcpl.com

Copyright © 2018 DKSORTHO & Sharma Pharmaceutical Pvt. Ltd., All Rights Reserved.
Design and Develop by Shri Narayan Infotech
Orthopedic Implants, Orthopaedic, Manufacturer,Large Fragment - Locked-Locked Plate Implants- Lateral Tibia Head Buttress Locked Plate ( Left & Right),Large Fragment - Locked,Locked Plate Implants, Lateral Tibia Head Buttress Locked Plate ( Left & Right)