Proximal Femur Locked Plate (Left & Right)
 Proximal Femur Locked Plate (Left & Right)

Proximal Femur Locked Plate (Left & Right)

DESCRIPTION

Plates are used in fractures of trochanteric region, Multifragmentaric fractures, Osteotomies of the proximal femur and also in fixation of osteopenic bone and fixation of nonunions or Malunions First proximal hole : 95° Second proximal hole : 120° Third proximal hole : 135°

Screw option: 6.5mm Cancellous/5.0mm Cortex Locked Screw, 


SUITABLE TROCHANTERIC FRACTURE OF FEMUR
SCREW 6.5MM & 5.0MM
PROFILE 19.0MM X 6.0MM
DISTANCE BETWEEN HOLE 18.0MM
MATERIAL STAINLESS STEEL 316L / 316LVM / TITANIUM
HOLES 4,5,6,7,8,9,10,11,12
PROXIMAL SCREW CANCELLOUS LOCKED SCREW 6.5MM
SCREW LENGTH 20.0MM TO 100.0MM (DIFF. 5.0MM)
DISTAL SCREW CORTEX LOCKED SCREW 5.0MM
SCREW LENGTH 20.0MM TO 64.0MM (DIFF. 5.0MM)
DESCRIPTION


HOLE LEFT RIGHT
HOLE CAT. No. S.S. CAT. No. TIT. CAT. No. S.S. CAT. No. TIT.
 
04 SP05.SS00241 SP05.TIT00241 SP05.SS00250 SP05.TIT00250
05 SP05.SS00242 SP05.TIT00242 SP05.SS00251 SP05.TIT00251
06 SP05.SS00243 SP05.TIT00243 SP05.SS00252 SP05.TIT00252
07 SP05.SS00244 SP05.TIT00244 SP05.SS00253 SP05.TIT00253
08 SP05.SS00245 SP05.TIT00245 SP05.SS00254 SP05.TIT00254
09 SP05.SS00246 SP05.TIT00246 SP05.SS00255 SP05.TIT00255
10 SP05.SS00247 SP05.TIT00247 SP05.SS00256 SP05.TIT00256
11 SP05.SS00248 SP05.TIT00248 SP05.SS00257 SP05.TIT00257
12 SP05.SS00249 SP05.TIT00249 SP05.SS00258 SP05.TIT00258

Latest Videos

Upcoming Events

About US

We are one of the first three companies of India to obtain Indian FDA (CDSCO) permission to manufacture Orthopedic Implants. We offer a wide & growing range of the highest quality orthopedic implants & instrumentation along with other associated product sat reasonable cost. We have got a sound and firm position in the orthopedic industry by having a sturdy network of distributors domestically & around the globe. We are having the most modern technologies and are one of the leading manufacturers (since 1992) with pinnacle superiority of Ortho-Implants and instrumentation's.
Read More...

SHARMA PHARMACEUTICAL PVT. LTD.

Address:
444, G.I.D.C Estate , Waghodia -391 760, Vadodara, Gujarat, India

Contact: +91-9825027792, 9227703191

Email: info@spcpl.com;

Website: https://www.spcpl.com

Copyright © 2018 Sharma Pharmaceutical Pvt. LTd, All Rights Reserved.
Design and Develop by Shri Narayan Infotech
Orthopedic Implants, Orthopaedic, Manufacturer,Large Fragment - Locked-Locked Plate Implants- Proximal Femur Locked Plate (Left & Right),Large Fragment - Locked,Locked Plate Implants, Proximal Femur Locked Plate (Left & Right)