Dynamic Compression Plate (dcp) Broad
 Dynamic Compression Plate (dcp) Broad

Dynamic Compression Plate (dcp) Broad

DESCRIPTION

Femur shaft fractures (Spiral, Segmental, Oblique) are indicated for these type of plates.The proximal and distal incisions are made, each incision is 5 to 7cm in length and is carried sharply through the iliotibial tract and vastus lateralis.

Screw option(non-locking):6.5mm Cancellous Screw, 4.5mm Cortical Screw

SUITABLE FOR FEMUR AND TIBIA SHAFT FRACTURE
SCREW 4.5MM & 6.5 MM
PROFILE 16.5MM X 5.0MM
DISTANCE BETWEEN HOLE 16.0MM
MATERIAL STAINLESS STEEL 316L / 316LVM / TITANIUM
HOLES 2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18
SHAFT PART CORTICAL SCREW 4.5MM
SCREW LENGTH 10.0MM TO 54.0MM (DIFF. 2.0MM)
SHAFT PART CORTICAL SCREW 6.5MM
SCREW LENGTH 20.0MM TO 120.0MM (DIFF. 2.0MM)
DESCRIPTION


HOLE CAT. NO. SS. CAT. NO. TIT.
 
02 SP05.SS01242 SP05.TIT01242
03 SP05.SS01243 SP05.TIT01243
04 SP05.SS01244 SP05.TIT01244
05 SP05.SS01245 SP05.TIT01245
06 SP05.SS01246 SP05.TIT01246
07 SP05.SS01247 SP05.TIT01247
08 SP05.SS01248 SP05.TIT01248
09 SP05.SS01249 SP05.TIT01249
10 SP05.SS01250 SP05.TIT01250
11 SP05.SS01251 SP05.TIT01251
12 SP05.SS01252 SP05.TIT01252
13 SP05.SS01253 SP05.TIT01253
14 SP05.SS01254 SP05.TIT01254
15 SP05.SS01255 SP05.TIT01255
16 SP05.SS01256 SP05.TIT01256
17 SP05.SS01257 SP05.TIT01257
18 SP05.SS01258 SP05.TIT01258

Latest Videos

Upcoming Events

About US

We are one of the first three companies of India to obtain Indian FDA (CDSCO) permission to manufacture Orthopedic Implants. We offer a wide & growing range of the highest quality orthopedic implants & instrumentation along with other associated product sat reasonable cost. We have got a sound and firm position in the orthopedic industry by having a sturdy network of distributors domestically & around the globe. We are having the most modern technologies and are one of the leading manufacturers (since 1992) with pinnacle superiority of Ortho-Implants and instrumentation's.
Read More...

SHARMA PHARMACEUTICAL PVT. LTD.

Address:
444, G.I.D.C Estate , Waghodia -391 760, Vadodara, Gujarat, India

Contact: +91-9825027792, 9227703191

Email: info@spcpl.com;

Website: https://www.spcpl.com

Copyright © 2018 Sharma Pharmaceutical Pvt. LTd, All Rights Reserved.
Design and Develop by Shri Narayan Infotech
Orthopedic Implants, Orthopaedic, Manufacturer,Large Fragment – Non Locked-Non Locked Implants Large- Dynamic Compression Plate (DCP) Broad,Large Fragment – Non Locked,Non Locked Implants Large, Dynamic Compression Plate (DCP) Broad