DESCRIPTION

Indications for trochanteric support locked plate are per trochanteric fracture or intertrochanteric fracture. Straight lateral skin incision about 15 cm long, beginning two finger breadths above the tip of the greater trochanter is placed for putting the plate and then split the iliotibial tract longitudinally from the tip of the trochanter distally.

Screw option: 12.5mm Lag Screw with Compression Screw, 5.0mm Cortex Locked Screw, 4.5mm Cortical Screw

Suitable for TROCHANTEIC FRACTURE ASSOCIATOR WITH FRACTURE OF THE GREATER TROCHANTERIC
SCREW 12.5MM, 6.5MM & 5.0MM
PROFILE 19.0MM X 6.0MM
DISTANCE BETWEEN HOLE 18.0MM
MATERIAL STAINLESS STEEL 316L / 316LVM / TITANIUM
HOLES 2 Hole to 20 Hole
DEGREE 130, 135
LAGSCREW 12.5MM 25.0MM TO 120.0MM (DIFF. 5.0MM)
SCREW CORTEX LOCKED SCREW 5.0MM
SCREW LENGTH 10.0MM TO 54.0MM (DIFF. 2.0MM)
SCREW CANCALLOUS LOCKED SCREW 6.5MM
SCREW LENGTH 20.0MM TO 120.0MM (DIFF. 5.0MM)
DESCRIPTION


HOLE CAT. No. S.S. CAT. No. TIT.
 
02 S23.SS15339 S23.TIT15339
03 S23.SS15340 S23.TIT15340
04 S23.SS15341 S23.TIT15341
05 S23.SS15342 S23.TIT15342
06 S23.SS15343 S23.TIT15343
07 S23.SS15344 S23.TIT15344
08 S23.SS15345 S23.TIT15345
09 S23.SS15346 S23.TIT15346
10 S23.SS15347 S23.TIT15347
11 S23.SS15348 S23.TIT15348
12 S23.SS15349 S23.TIT15349
13 S23.SS15350 S23.TIT15350
14 S23.SS15351 S23.TIT15351
15 S23.SS15352 S23.TIT15352
16 S23.SS15353 S23.TIT15353
17 S23.SS15354 S23.TIT15354
18 S23.SS15355 S23.TIT15355
19 S23.SS15356 S23.TIT15356
20 S23.SS15357 S23.TIT15357

Latest Videos

Upcoming Events

About US

We are one of the first three companies of India to obtain Indian FDA (CDSCO) permission to manufacture Orthopedic Implants. We offer a wide & growing range of the highest quality orthopedic implants & instrumentation along with other associated product sat reasonable cost. We have got a sound and firm position in the orthopedic industry by having a sturdy network of distributors domestically & around the globe. We are having the most modern technologies and are one of the leading manufacturers (since 1992) with pinnacle superiority of Ortho-Implants and instrumentation's.
Read More...

Membership
  • US FDA
  • Indian FDA
  • Federation of Gujarat Industries (FGI)
  • Federation of Indian Chambers of Commerce and Industry(FICCI)
  • Orthopedic implants Manufacturer asosiationasosiation
DKSORTHO & Sharma Pharmaceutical Pvt. Ltd..

Address:
444, G.I.D.C Estate , Waghodia -391 760, Vadodara, Gujarat, India

Contact: +91-9825027792, 9227703191

Email: info@spcpl.com;

Website: https://www.spcpl.com

Copyright © 2018 DKSORTHO & Sharma Pharmaceutical Pvt. Ltd., All Rights Reserved.
Design and Develop by Shri Narayan Infotech
Orthopedic Implants, Orthopaedic, Manufacturer,Large Fragment - Locked-Locked Plate Implants- Trochanteric Support Locked Plate,Large Fragment - Locked,Locked Plate Implants, Trochanteric Support Locked Plate